Monitoring NetApp Primary storage series of Filers
OpStor provides monitoring and management of NetApp Filers
Models Supported
- NetApp FAS
- FAS2200 Series
- FAS3200 Series
- FAS6200 Series
- FAS200
- FAS250
- FAS270
- FAS270c
- FAS 900c
- FAS 920
- FAS920c
- FAS940
- FAS940c
- FAS960
- FAS960c
- FAS980
- FAS980c
- FAS2050
- FAS3000
- FAS3020
- FAS3050
- FAS3070
- FAS6040
- FAS6080
- NetApp F-500, F-600 & F-700 series
- F825c
- F825
- F210
- F230
- F520
- F630
- F720
- F740
- F760
- C Series
For monitoring NetApp filers, OpStor uses two methods
- Monitoring via SNMP
- Monitoring via SDK API
Monitoring via SNMP :
Features supported
Inventory Details |
Logical Details |
Monitors |
Report Details |
- Raid details
- Fibre channel ports
|
- Quota Information
- CPU utilization
- Cluster details
- Volume usage details
|
- Fan
- Battery
- Power Supply
- Sensors
|
- Capacity Summary
- Availability
- Array performance reports
- Interconnect details
|
Prerequisites for monitoring NetApp Filers in OpStor
- Ensure SNMP agent is running.
- Register OpStor server IP address as trap destination
Steps to add NetApp Array OpStor
- Navigate to Admin Tab --> Manage Storage Devices link in OpStor client
- Provide IP Address of NetApp Filer
- Choose Device Type as 'RAID'
- Choose Vendor as 'NetApp'
- Choose the Model as 'SNMP Supported'
- Provide SNMP Port and Community string (default is 161 and public)
- If needed, change the Timeout value (default is 5 seconds)
- Click on Add Device
Note : If the Ping facility is disabled for the device, then please uncheck 'Ping the given IP' field.
Note : In case of non discovery of the device, please follow the troubleshooting tips displayed in the webclient and try re-adding the device.
Monitoring via SDK API :
Features supported (when monitored through SDK API)
Inventory Details |
Logical Details |
Monitors |
Report Details |
|
- Aggregate
- Volumes
- LUN
- Qtree
- Quota Info
|
- Array Status
- Drive status
- Volume status
- Components Status
|
- Capacity Summary
- Availability
- Performance
|
Prerequisites for monitoring NetApp Filers using SDK API
- OpStor uses SDK API to monitor the NetApp Filers
- Ensure that the API is installed on the Filer
Steps to add NetApp Filers into OpStor(through SDK API)
- Navigate to Admin Tab --> Manage Storage Devices link in OpStor client
- Provide IP Address of NetApp Filer
- Choose the Device Type as 'RAID'
- Choose the Vendor as 'NetApp'
- Choose the Model as 'SDKAPI Supported'
- In Username field enter the SDK API username
- In the Password field enter the SDK API password
- Change the Timeout, if needed
- Click on Add Device.
Note : If the Ping facility is disabled for the device, then please uncheck 'Ping the given IP' field.
Note : In case of non discovery of the device, please follow the troubleshooting tips displayed in the webclient and try re-adding the device.